Showing 17–30 of 30 results
-
CHF184.01 – CHF188.50Price range: CHF184.01 through CHF188.50
Product: MSK-SFM-12 Ball Mill Accessories Application: Powder mixing and electrode slurry preparation Product Overview: Accessories for the MSK-SFM-12 ball mill. The 2015DP clamp fixture holds milling vials securely through the mixing cycle, and conical-bottom tubes are available separately for small-batch powder handling. Available Configurations: 2015DP Ball Mill Clamp / Fixture 2ml Conical Bottom Tube (50…
-
CHF171.67 – CHF255.82Price range: CHF171.67 through CHF255.82
MSK-T10 Disc Cutter Die / Punching Mold Application: Cutting for coin cell battery electrodes and separators Product Overview: Compatible with MSK-T10 manual disc cutter, available in standard and customized sizes for laboratory research. Key Specifications: Diameter Range: 3 mm – 24 mm (Standard) Extended Range: 25 mm – 26 mm (Available) Customization: Non-integer diameters available…
-
CHF161.57 – CHF192.99Price range: CHF161.57 through CHF192.99
NCM (Nickel Cobalt Manganese) Cathode Sheet (Single/Double-Sided Coated Aluminum Foil) Application: Cathode Material for Lithium-ion Batteries Product Overview: The product has a Nickel Cobalt Manganese (NCM622) coating on an aluminum current collector, processed with calendering. It is designed for lithium-ion battery research. Specifications (Single-Sided Reference): Sheet Dimensions: 241 mm L x 200 mm W Coated…
-
CHF188.50 – CHF200.84Price range: CHF188.50 through CHF200.84
NCM 9-Series (Nickel Cobalt Manganese) Cathode Sheet (Single/Double-Sided Coated Aluminum Foil) Application: Cathode Material for Lithium-ion Batteries Product Overview: This product features a Nickel Cobalt Manganese (NCM 9-Series) coating on an aluminum current collector. It is designed for lithium-ion battery research. Key Specifications (Double-Sided Reference): Sheet Dimensions: 241 mm L x 200 mm W Coated…
-
CHF134.64 – CHF141.37Price range: CHF134.64 through CHF141.37
NCM111 (Nickel Cobalt Manganese) Cathode Sheet (Single/Double-Sided Coated Aluminum Foil) Application: Cathode Material for Lithium-ion Batteries Product Overview: The product has a Nickel Cobalt Manganese (NCM111) coating on an aluminum current collector, processed with calendering. It is available in single and double-sided configurations, designed for lithium-ion battery research. Specifications (Common Parameters): Sheet Dimensions: 241 mm…
-
CHF134.64 – CHF161.57Price range: CHF134.64 through CHF161.57
NCM523 (Nickel Cobalt Manganese) Cathode Sheet (Single/Double-Sided Coated Aluminum Foil) Application: Cathode Material for Lithium-ion Batteries Product Overview: The product has a Nickel Cobalt Manganese (NCM523) coating on an aluminum current collector, processed with calendering. It is designed for lithium-ion battery research. Specifications (Single-Sided Reference): Sheet Dimensions: 241 mm L x 200 mm W Coated…
-
CHF175.03 – CHF188.50Price range: CHF175.03 through CHF188.50
Product: NCM811 (Nickel Cobalt Manganese) Cathode Sheet (Single/Double-Sided Coated Aluminum Foil) Application: Cathode Material for Lithium-ion Batteries Product Overview: The product has a Nickel Cobalt Manganese (NCM811) coating on an aluminum current collector, processed with calendering. It is available in both single-sided and double-sided configurations to meet the listed lithium-ion battery research configurations. Specifications (Single-Sided…
-
CHF107.71 – CHF201.96Price range: CHF107.71 through CHF201.96
S-MP-7580 Pouch Cell Compression Test Fixture for Li-S/Li-ion Batteries Application: Pressurized Cyclic Testing of Pouch Cells (Li-S, Li-ion Systems) Product Overview: Model S-MP-7580 is a specialized testing clamp designed for pouch battery cells. It consists of upper and lower plates and guide screws, providing structure, construction, and pressure across the cell surface during cycling. It…
-
CHF173.91
Product: Pouch Cell Lithium Battery Fireproof Bag Application: Storage and transport of lithium pouch cells Product Overview: Fireproof bags for storing and moving lithium-ion and lithium-sulfur pouch cells. Laboratory safety procedures commonly require cells held outside a dedicated cabinet to be bagged in this way. Available Configurations: 230 x 300 mm, 10 pcs
-
CHF134.64
Product: Single-Sided Carbon-Sulfur Composite Cathode Sheet (High Loading, CF-SHEET) Application: Cathode Material for Lithium-Sulfur (Li-S) Batteries Product Overview: This high-loading cathode sheet features a carbon-sulfur composite coated on an aluminum foil substrate. It offers high electrical conductivity and is used in Lithium-Sulfur batteries. Dimensions: 50 mm x 80 mm Sulfur Loading (Single-Sided): 3.9 ± 0.1…
-
CHF154.84
Single-Sided LCO Cathode Disc on Aluminum Foil (Dia. 15 mm) Application: Cathode Material for Lithium-ion Batteries Product Overview: This product consists of Lithium Cobalt Oxide (LCO) single-sided coated aluminum foil, cut into discs and ready for coin cell assembly. Key Specifications (Single-Sided): Disc Diameter: 15 mm Total Thickness: 58 µm Coating Type: Single-Sided Current Collector…
-
CHF154.84
Single-Sided Lithium Iron Phosphate (LFP) Cathode Discs on Aluminum Foil (Dia. 15 mm) Application: Cathode Material for Lithium-ion Batteries Product Overview: This product consists of a Lithium Iron Phosphate (LFP) single-sided coating on an aluminum current collector, cut into discs and ready for coin cell assembly. Key Specifications (Single-Sided Reference): Disc Diameter: 15 mm Total…
-
CHF175.03
Single-Sided NCM811 (Nickel Cobalt Manganese) Cathode Discs on Aluminum Foil (Dia. 15 mm) Application: Cathode Material for Lithium-ion Batteries Product Overview: This product consists of a Nickel Cobalt Manganese (NCM811) single-sided coating on an aluminum current collector, cut into discs and ready for coin cell assembly. Key Specifications (Single-Sided Reference): Disc Diameter: 15 mm Coating…
-
CHF170.55
Transparent Acrylic Pouch Cell Splint Set Application & Overview: This kit is an auxiliary device applicable for pouch cell measurement. It adopts two-plate surface clamping to hold the cell, and long-tail fixation to secure the cell. This design achieves flat contact between the internal electrode sheet and separator under fixed pressure during pouch-cell measurement. The…